Intra-Operative Pulse Oximetry OPEN ACCESS

[+] Author and Article Information
L. Oliveira, M. Bikson

 The City College of New York of CUNY, USA Memorial Sloan-Kettering Cancer Institute, USA

E. Servais, N. Rizk, P. Adusumilli

 The City College of New York of CUNY, USA Memorial Sloan-Kettering Cancer Institute, USA

J. Med. Devices 3(2), 027554 (Jul 24, 2009) (1 page) doi:10.1115/1.3155371 History: Published July 24, 2009

Abstract

Bowel resection surgery is a commonly performed operation used to treat a variety of gastro-intestinal tract disorders, including cancer. The surgery entails excising the diseased portion of intestine, and then creating a surgical anastomosis, or reattachment of the remaining ends. One of the major complications following bowel resection surgery is breakdown or leakage from the anastomosis, which affects 20% of patients, with an associated 10-15% mortality rate. The surgical creation of anastomosis frequently involves dividing blood vessels and can introduce unrecognized twists and tension on the intestine. As a result, the blood supply to the site of anastomosis is often hampered, limiting the oxygen supply that is essential for adequate anastomotic healing. We are proposing a device that enables surgeons to obtain real-time feedback on local tissue oxygen saturation (SpO2) during operative procedures. Such data will not only help surgeons realize any bowel oxygenation compromising maneuvers, but also help perform an anastomosis at the site of maximal tissue oxygenation, thus minimizing the occurrence of postoperative anastomotic leakage and improve patient outcomes. This report details the specifications, fabrication, operation and performance of a handheld wireless pulse oximeter suitable for the intraoperative measurement of tissue SpO2 during bowel surgery. The device adapts principles and technology developed for non-invasive pulse oximetry, and introduces tissue interface, physician tools, and signal processing algorithms for intra-operative application. The handheld device includes local display of SpO2 level (<1s refresh) at the contacted tissue, and signals the operator on degraded signal quality/faults. An onboard micro-controller digitizes and processes signals transduced through a controlled LED array. Signal processing and display parameters were optimized for operating room conditions. A disposable functionally-transparent cover provides both device and tissue protection. Through serial or Bluetooth wireless transmission (250 Kbps), SpO2 and pulse signals can be processed on a PC or operating room VI. The incorporation of a pressure sensor to increase accuracy and robustness is explored. The device was validated intra-operatively on rodent and bovine surgical models.

Copyright © 2009 by American Society of Mechanical Engineers
This article is only available in the PDF format.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In