0
2008 Design of Medical Devices Conference Abstracts

Dynamic Behavior of SMA Actuated Catheter OPEN ACCESS

[+] Author and Article Information
Arun S. Veeramani, Gregory D. Buckner, Stephen B. Owen, John H. Crews, Richard C. Cook, Gil Bolotin

 North Carolina State University, Raleigh, NC, USA

J. Med. Devices 2(2), 027556 (Jun 25, 2008) (1 page) doi:10.1115/1.2936116 History: Published June 25, 2008

Abstract

Introduction: While catheters have proven effective in numerous cardiovascular procedures, their functionality and versatility can be greatly improved by incorporating active steering capabilities to the catheter tip. Shape memory alloy (SMA) actuation is ideally suited to this application, as these materials offer superior power density, energy density and biocompatibility. In this research, we investigate the transient behavior of an SMA-actuated active catheter to optimize its design and enable precise computer-controlled navigation. Methods: The active catheter prototype consists of a central beam actuated by a single SMA tendon, both enclosed by an outer Teflon sleeve. Joule heating is used to generate tip deflections, which are measured in real time using a dual-camera imaging system. SMA actuation is described using the Seelecke-Muller-Achenbach single-crystal model whose parameters are experimentally derived from stress-strain characteristics of the SMA tendon measured at different temperatures. These characteristics are used to optimize the design parameters of the catheter to maximize the bending response. The effects of outer sleeve thickness on the transient behavior of the catheter are also studied. Results: The catheter’s bending mechanics are described using a circular arc model, which is experimentally validated. Catheter actuation is found to be slower with increased sleeve thickness, as explained by heat transfer analysis. Dynamic simulation of the system model shows excellent correlation to experimental data for low frequency actuation.

Copyright © 2008 by American Society of Mechanical Engineers
Topics: Catheters
This article is only available in the PDF format.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In