Continuous In Vivo Monitoring of a Flexible Subcutaneous Sensor in Freely Moving Diabetic Rats OPEN ACCESS

[+] Author and Article Information
Spencer Thomas

 Access Systems, Salt Lake City, UT

Robert Hitchcock

 University of Utah, Salt Lake City, UT, USA

J. Med. Devices 2(2), 027517 (Jun 11, 2008) (1 page) doi:10.1115/1.2936213 History: Published June 11, 2008

Abstract

Subcutaneous tissue is frequently the target site for placement of continuous, real-time metabolic sensors. Since the 1960s, numerous research groups have developed needle-like sensor designs, patterned after the Clarke Electrode, to monitor glucose in subcutaneous tissue. These designs perform well in vitro but often fail in vivo due to sensor instability and tissue response. None of these studies focused on the mechanical properties of implanted sensors and how these properties may affect in vivo performance. To investigate the role of sensor stiffness on short term functionality we developed a low stiffness subcutaneous sensor patterned after the Clarke Electrode and tested it in rodents. The purpose of this study was two-fold. The first goal was to demonstrate the in vivo functionality of the flexible sensor. The second goal was to evaluate the effect of stiffness on functionality by co-implanting stiff and flexible sensors. In the first series of studies the low stiffness sensors provided glucose level measurements that fell within the A and B regions of the Clarke Error Grid 93.0% of the time. The results of the second study yielded similar accuracy; however, no performance difference was seen between the stiff and flexible sensors. We concluded that the flexible sensor works for at least 3days after implantation in the subcutaneous tissue of freely moving rats and that the key property of low stiffness has no differential effect on the accuracy of the sensor in the freely moving rodent model of these studies.

Copyright © 2008 by American Society of Mechanical Engineers
This article is only available in the PDF format.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In