0
2009 Design of Medical Devices Conference Abstracts

Microfabrication of a Device to Evaluate the Swelling of Glucose Sensitive Hydrogels Under Isochoric Conditions OPEN ACCESS

[+] Author and Article Information
D. Barriet, R. A. Siegel

Department of Pharmaceutics,  University of Minnesota, Minneapolis, USA

J. Med. Devices 3(2), 027519 (Jul 08, 2009) (1 page) doi:10.1115/1.3136753 History: Published July 08, 2009

Abstract

Diabetes has been the focus of intense research for more than half a century both in academia and in industry. The number of diabetes cases (especially type II) continues to increase due to the obesity pandemic in western societies and the cost of treatment of diabetes and its severe side effects will undoubtedly continue to drive development of wide ranging technological means to better understand and treat diabetes. Tight blood sugar regulation has been shown to delay or limit side effects and prolong lifespan in patients. Continuous glucose monitoring (CGM) is expected to provide information that can be used in better regulating patient behavior, or as part of a closed loop feedback control system for administering insulin at appropriate times. Our approach to CGM involves a hydrogel whose swelling depends on glucose concentration, coupled to an LC microresonator circuit, whose resonant frequency depends on hydrogel swelling due to impingment of the hydrogel on one plate of the microcapacitor. The whole sensor is microfabricated and implantable. Wireless determination of the resonant frequency permits continuous glucose sensing without chronic skin breach. We are in the process of designing hydrogels that swell/shrink with decreasing/increasing glucose concentration to test for hypoglycemia or hyperglycemia. In collaboration with Professor Babak Ziaie's group at Purdue, a first generation microdevice was fabricated. Since the full sensor requires a significant investment in time and money for its fabrication, the incorporation and testing of diverse hydrogel systems in the full device is unrealistic at the present stage of development. We are currently fabricating a testbed device to allow for the selection of lead hydrogels, which will evaluate quantitatively the relationship stimuli/pressure. Few examples exist in the literature to measure the swelling pressure of hydrogels under isochoric conditions (V=constant) experimentally. We will describe our progress toward the fabrication of a test device to evaluate the pressure developed by a hydrogel sample inside a cavity. We used a commercial pressure die with a very small piezoresistive element (500μm by 500μm), and packaged it such that the pressure sensitive membrane was in contact with a hydrogel sample a few tens of μm thin separated from the external environment by a commercial Anodisc? membrane (0.02 and 0.2 μm pore diameter). Details of design and preliminary results will be presented.

Copyright © 2009 by American Society of Mechanical Engineers
This article is only available in the PDF format.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In