Vaginal Approach for Uterus Separation During Laparoscopic Hysterectomy OPEN ACCESS

[+] Author and Article Information
Mart M. C. Gahler, Nick N. J. van de Berg, John van den Dobbelsteen

Delft University of Technology

Johann Rhemrev

Bronovo Hospital

Frank W. Jansen

Leiden University Medical Center

J. Med. Devices 4(2), 027514 (Aug 09, 2010) (1 page) doi:10.1115/1.3442765 History: Published August 09, 2010; Online August 09, 2010

Abstract

Every year more than 15.000 total hysterectomy procedures are performed in the Netherlands. From all these procedures, only a minor part is done via a laparoscopic approach. One reason for this is the high complexity of the procedure. The uterus is difficult to reach with the laparoscopic tools and nearby structures are easily damaged. Especially, the separation of the uterus at the fornix needs to be done with great care and is time consuming (i.e., typically takes more than 15–20 min). This results in long procedure times. To resolve part of these difficulties, a new instrument has been designed that enables separation of the uterus via a vaginal approach. The device uses a cutting mechanism to safely separate the uterus from the vagina wall. The design allows the application of an existing manipulator to mobilize the uterus for better access of laparoscopic tools. A prototype of the separation tool, MobiSep, has been manufactured. The new separation principle has been evaluated in a test setup. Over the device a tubular piece of tissue was mounted, resembling the vagina wall. The results show that the time needed for full separation is on average 102 (s). The maximum driving force needed to cut the tissue is found to be 50 (N), which can be applied manually. It is expected that this prototype is intuitive to use, can contribute to the reduction of the complexity of laparoscopic hysterectomy procedures and can reduce the total procedure time.

Copyright © 2010 by American Society of Mechanical Engineers
This article is only available in the PDF format.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In