2010 Design of Medical Devices Conference Abstracts

3D Foot Plate For Diagnosis of Abnormal Range of Motion in the Hindfoot OPEN ACCESS

[+] Author and Article Information
Gabrielle J. M. Tuijthof

Department of Biomechanical Engineering, Delft University of Technology

Martina Pontesilli, Leendert Blankevoort

Department of Orthopedic Surgery, Orthopedic Research Center Amsterdam, Academic Medical Centre

Hanneke van der Zwaag, Stefan G. van de Geer

Faculty of Industrial Design Engineering, Delft University of Technology

Remmet Jonges

Department of Biomedical Engineering and Physics, Academic Medical Centre

Mario Maas

Department of Radiology, Academic Medical Centre

J. Med. Devices 4(2), 027517 (Aug 10, 2010) (1 page) doi:10.1115/1.3443168 History: Published August 10, 2010

Abstract

Careful diagnosis of ankle joints with suspected ligamentous trauma is necessary. Accurate 3D stress test techniques can assist in this but the devices used to stress the foot relative to the lower leg are inapt for clinical application. The goal was to evaluate whether a newly designed 3D foot plate fulfills the requirements of the intended users who are the radiology technicians and the patients. Criteria on functionality included position and fixation of the foot in extreme dorsiflexion (45Å), plantarflexion (85Å), inversion (55Å), eversion (55Å), internal (50Å) and external rotation (50Å), compatibility with imaging systems, and sufficient accuracy and reliability. Criteria on usability included the presence of sense of control by manual loading, successful application in 95% of an adult human population, operation within around 100 s. and low mental effort by self-explaining capability of the device. The design was based on a Stewart platform. The dimensions were determined graphically and a fixation mechanism was developed based on friction. A prototype was built from wood and plastics. This was evaluated in a CT-scanner for accuracy and reliability with four subjects. A usability test was performed with 20 radiology technicians who were asked to perform four tasks with the prototype and fill out a questionnaire. The prototype can reach all extreme foot positions for adults with varying anthropometric dimensions. Except two outliers, the accuracy of reaching an extreme foot position is 0.36Å and its reliability is 0.33.5Å. All radiology technicians agreed that the device could be operated by one person with minor physical and mental effort (NASA XLT median 3.5–11%). The tasks were executed with a median time of 91 s. (20–513 s.) and a median error of 0 (0–6). Its appearance was found professional and reliable. Improvement of the rubber hinges, the fixation mechanism and loading protocol could increase accuracy. Concluding, the 3D foot plate fulfills the majority of criteria and is well-received by the intended users. This demonstrates its high potential for clinical use.

Copyright © 2010 by American Society of Mechanical Engineers
This article is only available in the PDF format.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In