0
Research Paper

Material Handling System for Robotic Natural Orifice Surgery

[+] Author and Article Information
Jeff Midday

Dept. of Mechanical & Materials Engineering,
University of Nebraska-Lincoln,
W342 Nebraska Hall,
Lincoln, NE 68588-0526
e-mail: jeff.midday@yahoo.com

Carl A. Nelson

Dept. of Mechanical & Materials Engineering,
University of Nebraska-Lincoln,
W342 Nebraska Hall
Lincoln, NE 68588-0526;
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: cnelson5@unl.edu

Alan Goyzueta

Dept. of Mechanical & Materials Engineering,
University of Nebraska-Lincoln,
W342 Nebraska Hall,
Lincoln, NE 68588-0526
e-mail: alangoyzueta@gmail.com

Dmitry Oleynikov

Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: doleynik@unmc.edu

Manuscript received May 9, 2012; final manuscript received November 16, 2012; published online February 4, 2013. Editor: Gerald E. Miller.

J. Med. Devices 7(1), 011003 (Feb 04, 2013) (7 pages) Paper No: MED-12-1069; doi: 10.1115/1.4023265 History: Received May 09, 2012; Revised November 16, 2012

Natural orifice translumenal endoscopic surgery (NOTES) is a relatively new surgical approach that uses no external incisions, thereby improving cosmetic outcomes, decreasing overall recovery time, and reducing the risk of external infection. In standard NOTES, flexible endoscopic tools have been used to carry out a variety of surgical procedures in the abdomen. As an alternative, miniature in vivo robots can be fully inserted into the peritoneal cavity and utilized to perform various surgical procedures. These in vivo robots eliminate tool triangulation issues, improve multitasking capabilities, and greatly increase freedom and dexterity when compared to standard endoscopic and laparoscopic tools. One major limitation is that once inserted, the in vivo robots are isolated within the abdomen and cannot send or receive materials to the external environment. The topic of this paper is a material handling system that has been developed to bridge this deficiency. This system features a flexible silicone overtube and an open-loop control system with manual and automatic operation capabilities. The system utilizes the helix of a spring to advance a payload (staples, robotic tool tips, etc.) along the length of the overtube. The system functioned as intended in benchtop and in vivo testing. Minimum bend radius was identified, and a payload was successfully advanced and retrieved through the shuttling system in porcine surgical procedures. NOTES access was achieved via a custom built transvaginal trocar. This paper presents the design and rationale, control strategy, and in vivo testing results for the NOTES material handling system. The system performs as intended based on functional requirements as demonstrated in benchtop and porcine in vivo testing. The control method is robust even when pushed beyond the physical constraints of the system. Collectively, the material handling system provides a simple, repeatable way for an operator to interface with miniature in vivo robots, improving surgical system flexibility while minimizing impact on the duration of an abdominal surgical procedure.

Copyright © 2013 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Fig. 1

Tract for NOTES transgastric approach

Grahic Jump Location
Fig. 2

In vivo robots [2,5] (copyright [2008], [2006] IEEE)

Grahic Jump Location
Fig. 3

NOTES material handling system

Grahic Jump Location
Fig. 4

Overtube selection array, top to bottom: silicone, braided vinyl, plain vinyl, extreme-temperature PTFE and corona-resistant PTFE

Grahic Jump Location
Fig. 5

Passive Nitinol spring grasper (light lines approximate deflected contour)

Grahic Jump Location
Fig. 6

Shuttle/overtube geometry (a) offset tab configuration, (b) shuttle tab configuration

Grahic Jump Location
Fig. 7

Primary functionality illustration

Grahic Jump Location
Fig. 8

Material handling system cross section

Grahic Jump Location
Fig. 9

Material handling control interface

Grahic Jump Location
Fig. 10

Inserted retention cap (left) and retracted insufflations cap (right). (1) Overtube, (2) grip pad, (3) motor coupling, (4) rotary insufflations seal, (5) magnetic attachment base, (6) fiberscope outlet, (7) 4 mm quick connect suction/irrigation fitting.

Grahic Jump Location
Fig. 11

Repeatability test: 12.7 cm bend radius, 180 deg axial twist test

Grahic Jump Location
Fig. 12

Bend radius orientations

Grahic Jump Location
Fig. 13

System inserted in vivo via GelPort®

Grahic Jump Location
Fig. 15

Transvaginal insertion of MHS: exterior (left), interior (right)

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org